Prices will be displayed as soon as your account has been created and activated by Witschi. To register
Close
New

Teslascope® Pulse

Fast demagnetization. Instant rate measurement. Clear diagnosis.

Detects
the magnetisation status of mechanical watches, movements and tools
Fast and effective
«one-shot» demagnetisation at the touch of a button
Automated process
for rate measurement and demagnetisation on the app for smartphones and tablets

Magnetic influences are among the most common causes of inaccurate mechanical watches. To avoid unnecessary servicing, additional effort, and uncertainty, the Teslascope Pulse provides immediate clarity: the watch is demagnetized while its rate values are measured simultaneously. A reliable initial assessment of the watchs condition is available within seconds of the customer′s first interaction.

The guided mode walks the user step by step through the testing process: place the watch, start the measurement. The system automatically performs the analysis and provides a clear evaluation of the watch’s condition along with the relevant rate values. This allows sales staff to give a well‑founded assessment without extensive technical knowledge. The measurement results appear directly on a smartphone or tablet via the Bluetooth app and can be easily explained during the customer consultation.

  • Detects the magnetisation status of mechanical watches, movements and tools
  • Fast and effective «one-shot» demagnetisation at the touch of a button (no need for cumbersome multiple demagnetisation in several positions)
  • Two operating modes: Measurement Sequence and Direct measurement
  • Power supply via USB-C port
  • Free app for display and operation via smartphone / tablet via Bluetooth

Technical specifications

Input / Output

Operation
Touch buttons and/or via the app
Display
LEDs and on the Teslascope Pulse app (for smartphones/tablets via Bluetooth)
Languages
App available in German, English and French

Measurement

Measuring Principle
Measurement of magnetisation using a magnetic field sensor array. Demagnetisation through pulse technology
Test Positions
DU dial up / DD dial down
Watch Types
Mechanical watches
Beat Rates
Automatic, 3'600 to 72'000 A/h
Time Base
TCXO (± 0.05 s/d)
Measurement Types
Global magnetisation and rate measurement
Measuring Range and Accuracy
Rate deviation: -327 ... +327 ± 1 s/d, magnetic range: 10mT
Measuring Programs
Automatic before-and-after measurement, including demagnetisation
Measuring Time
Approx. 90 seconds for a complete before-and-after measurement, including demagnetisation

Results

Numerical Display
Rate and magnetic field display
Graphic Display
3 levels of LED colours for magnetisation strength, magnetic field display and rate measurement on the Teslascope Pulse app

Device Data

Item No.
26.75PK1
Dimensions (packaged)
160 × 135 × 115 mm
Weight (packaged)
1.5 kg
Mains Connection
AC/DC USB-C adapter, 5V 15W (included)
Interfaces
USB, Bluetooth

Accessories

Do you have questions?

Do you need help choosing the right product?
We will be happy to advise you.